BuildHere

RM7 zoning in the District of North Vancouver: what can you build?

Multiple-Family Residential 7

On a standard lot with a rear lane, RM7 allows up to 2 units on a 33 × 122 ft lot (townhouses); up to 3 units on a 50 × 122 ft lot (townhouses); up to 4 units on a 66 × 122 ft lot (townhouses). These figures come from running BuildHere’s engine on each lot size with the District of North Vancouver rules for this zone.

Most units by lot size

Lot (with lane)Most unitsBuilding formMax floor area
33 × 122 ft4,026 sq ftUp to 2 unitsTownhouses3,221 sq ft
50 × 122 ft6,100 sq ftUp to 3 unitsTownhouses4,880 sq ft
66 × 122 ft8,052 sq ftUp to 4 unitsTownhouses6,441 sq ft

Building options on a 33 × 122 ft lot

OptionStatusUnitsMax floor area
TownhousesAllowed23,221 sq ft

Size limits for townhouses on a 33 × 122 ft lot

Max floor area (FSR 0.80)3,221 sq ftDNV RM7 s.555.2
Max height32.0 ft, about 3 storeysDNV RM7 s.553.1, Table 553.1
Site coverage60% of siteDNV RM7 s.555.3
Front setback0.0 ftDNV RM7 s.408
Side setback0.0 ftDNV RM7 s.408
Rear setback0.0 ftDNV RM7 s.408
Rough building footprintup to 2,411 sq ftEstimate, not a design
Parking stalls required4 stalls (minimum)DNV s.1001 Residential (4)

Source: District of North Vancouver Zoning Bylaw 3210, Part 5: Sections 550 to 560 (Multiple-Family Zones RM and Low-Rise Residential Zones RL), July 2026 consolidation (rules approved 2026-10-15)

Your lot will differ.

Frontage, depth, lane access, corner lots and frequent-transit areas all change the answer. Search your address for a report on the real lot in the District of North Vancouver.

Check your address →orfind it on the map →

Common questions

How many units can I build in RM7 zoning in the District of North Vancouver?

With a rear lane and outside a frequent-transit area, RM7 allows up to 2 units on a 33 × 122 ft lot (townhouses); up to 3 units on a 50 × 122 ft lot (townhouses); up to 4 units on a 66 × 122 ft lot (townhouses). Your own lot's frontage, depth and location change the result.

What is FSR?

Floor space ratio (FSR) is a building’s total floor area divided by the lot area. An FSR of 1.0 on a 4,026 sq ft lot allows about 4,026 sq ft of floor area across all storeys. Some bylaws, such as Burnaby’s R1, set no FSR at all; there BuildHere shows an effective FSR worked out from the height, setback and lot coverage limits.

Where do these RM7 rules come from?

From District of North Vancouver Zoning Bylaw 3210, Part 5: Sections 550 to 560 (Multiple-Family Zones RM and Low-Rise Residential Zones RL), July 2026 consolidation (rules approved 2026-10-15). Preliminary screening only. Verify with the District of North Vancouver.

Other District of North Vancouver zones

R1R2RS1RS2RS3RS4RS5RM1RM2RM3RM5RM6RL1RL2RL3RL4RSDRSKLRSMFRSNQRSPHRSEWRSHRSQRH1RH2RH3