BuildHere

RG-1A zoning in West Vancouver: what can you build?

Ground-Oriented Dwelling 1A

On a standard lot with a rear lane, RG-1A allows about 2 units on a 33 × 122 ft lot (ground-oriented dwellings); about 3 units on a 50 × 122 ft lot (ground-oriented dwellings); about 4 units on a 66 × 122 ft lot (ground-oriented dwellings). These figures come from running BuildHere’s engine on each lot size with the West Vancouver rules for this zone.

Most units by lot size

Lot (with lane)Most unitsBuilding formMax floor area
33 × 122 ft4,026 sq ftAbout 2 unitsGround-oriented dwellings2,415 sq ft
50 × 122 ft6,100 sq ftAbout 3 unitsGround-oriented dwellings3,660 sq ft
66 × 122 ft8,052 sq ftAbout 4 unitsGround-oriented dwellings4,831 sq ft

Building options on a 33 × 122 ft lot

OptionStatusUnitsMax floor area
Single family dwellingAllowed12,013 sq ft
Single family dwelling with secondary suiteAllowed22,013 sq ft
Single family dwelling with detached secondary suiteAllowed22,013 sq ft
Ground-oriented dwellingsAllowedAbout 22,415 sq ft

Size limits for ground-oriented dwellings on a 33 × 122 ft lot

Max floor area (FSR 0.60)2,415 sq ftWV RG-1A s.261.06
Max height25.0 ft, about 2 storeysWV RG-1A s.261
Site coverage40% of siteWV RG-1A s.261
Front setback15.0 ftWV RG-1A s.261
Side setback5.0 ftWV RG-1A s.261
Rear setback15.0 ftWV RG-1A s.261
Rough building footprintup to 1,615 sq ftEstimate, not a design
Parking stalls required2 stalls (minimum)WV s.141, 144

Source: District of West Vancouver Zoning Bylaw No. 4662, 2010: Section 200 (RS1 to RS10, RS2-UL, RS3-UL, RS8-UL, RS10-UL), Section 250 (RD1 to RD3, small-scale multi-unit housing, Bylaw 5351), Section 260 (RG-1A to RG-3) and Section 300 (RM1 to RM5), Section PDFs published on westvancouver.ca, with amendments to Bylaw 5351 (2024); the list of amendments is dated April 2026 consolidation (rules approved 2026-10-19)

Your lot will differ.

Frontage, depth, lane access, corner lots and frequent-transit areas all change the answer. Search your address for a report on the real lot in West Vancouver.

Check your address →orfind it on the map →

Common questions

How many units can I build in RG-1A zoning in West Vancouver?

With a rear lane and outside a frequent-transit area, RG-1A allows about 2 units on a 33 × 122 ft lot (ground-oriented dwellings); about 3 units on a 50 × 122 ft lot (ground-oriented dwellings); about 4 units on a 66 × 122 ft lot (ground-oriented dwellings). Your own lot's frontage, depth and location change the result.

What is FSR?

Floor space ratio (FSR) is a building’s total floor area divided by the lot area. An FSR of 1.0 on a 4,026 sq ft lot allows about 4,026 sq ft of floor area across all storeys. Some bylaws, such as Burnaby’s R1, set no FSR at all; there BuildHere shows an effective FSR worked out from the height, setback and lot coverage limits.

Where do these RG-1A rules come from?

From District of West Vancouver Zoning Bylaw No. 4662, 2010: Section 200 (RS1 to RS10, RS2-UL, RS3-UL, RS8-UL, RS10-UL), Section 250 (RD1 to RD3, small-scale multi-unit housing, Bylaw 5351), Section 260 (RG-1A to RG-3) and Section 300 (RM1 to RM5), Section PDFs published on westvancouver.ca, with amendments to Bylaw 5351 (2024); the list of amendments is dated April 2026 consolidation (rules approved 2026-10-19). Preliminary screening only. Verify with the District of West Vancouver.

Other West Vancouver zones

RS1RS2RS3RS4RS5RS6RS7RS8RS9RS10RS2-ULRS3-ULRS8-ULRS10-ULRD1RD2RD3RG-1BRG-2RG-3RM1RM2RM3RM4RM5