BuildHere

RRh zoning in Port Coquitlam: what can you build?

Residential Rowhouse

On a standard lot with a rear lane, RRh allows up to 2 units on a 33 × 122 ft lot (rowhouse); up to 3 units on a 50 × 122 ft lot (rowhouse); up to 4 units on a 66 × 122 ft lot (rowhouse). These figures come from running BuildHere’s engine on each lot size with the Port Coquitlam rules for this zone.

Most units by lot size

Lot (with lane)Most unitsBuilding formMax floor area
33 × 122 ft4,026 sq ftUp to 2 unitsRowhouse5,016 sq ft
50 × 122 ft6,100 sq ftUp to 3 unitsRowhouse7,585 sq ft
66 × 122 ft8,052 sq ftUp to 4 unitsRowhouse10,033 sq ft

Building options on a 33 × 122 ft lot

OptionStatusUnitsMax floor area
RowhouseAllowed25,016 sq ft

Size limits for rowhouse on a 33 × 122 ft lot

Max floor area (FSR 1.25)5,016 sq ftPOCO RRh s.Table 2.4
Max height34.4 ft, about 3 storeysPOCO RRh s.Table 2.4
Site coverage55% of sitePOCO RRh s.Table 2.4
Front setback9.8 ftPOCO RRh s.Table 2.4
Side setback0.0 ftPOCO RRh s.Table 2.4
Rear setback24.6 ftPOCO RRh s.Table 2.4
Rough building footprintup to 2,217 sq ftEstimate, not a design
Parking stalls required4 stalls (minimum)POCO s.8

Source: City of Port Coquitlam Zoning Bylaw, 2008, No. 3630, Section II, Part 2 (Residential Zones: Tables 2.2, 2.3, 2.4 and Section 2.5), Current consolidated bylaw on portcoquitlam.ca, as amended through the small-scale multi-unit housing amendments (2024) and later consolidation (rules approved 2026-10-19)

Your lot will differ.

Frontage, depth, lane access, corner lots and frequent-transit areas all change the answer. Search your address for a report on the real lot in Port Coquitlam.

Check your address →orfind it on the map →

Common questions

How many units can I build in RRh zoning in Port Coquitlam?

With a rear lane and outside a frequent-transit area, RRh allows up to 2 units on a 33 × 122 ft lot (rowhouse); up to 3 units on a 50 × 122 ft lot (rowhouse); up to 4 units on a 66 × 122 ft lot (rowhouse). Your own lot's frontage, depth and location change the result.

What is FSR?

Floor space ratio (FSR) is a building’s total floor area divided by the lot area. An FSR of 1.0 on a 4,026 sq ft lot allows about 4,026 sq ft of floor area across all storeys. Some bylaws, such as Burnaby’s R1, set no FSR at all; there BuildHere shows an effective FSR worked out from the height, setback and lot coverage limits.

Where do these RRh rules come from?

From City of Port Coquitlam Zoning Bylaw, 2008, No. 3630, Section II, Part 2 (Residential Zones: Tables 2.2, 2.3, 2.4 and Section 2.5), Current consolidated bylaw on portcoquitlam.ca, as amended through the small-scale multi-unit housing amendments (2024) and later consolidation (rules approved 2026-10-19). Preliminary screening only. Verify with the City of Port Coquitlam.

Other Port Coquitlam zones

RS1RS2RS3RS4RTh1RTh2RTh3RTh4RA1RA2