BuildHere

FSD zoning in Vancouver: what can you build?

First Shaughnessy District

On a standard lot with a rear lane, FSD allows up to 6 units on a 33 × 122 ft lot (multiple dwelling); up to 6 units on a 50 × 122 ft lot (multiple dwelling); up to 6 units on a 66 × 122 ft lot (multiple dwelling). These figures come from running BuildHere’s engine on each lot size with the Vancouver rules for this zone.

Most units by lot size

Lot (with lane)Most unitsBuilding formMax floor area
33 × 122 ft4,026 sq ftUp to 6 unitsMultiple dwelling (4 to 8 units)567 sq ft
50 × 122 ft6,100 sq ftUp to 6 unitsMultiple dwelling (4 to 8 units)3,050 sq ft
66 × 122 ft8,052 sq ftUp to 6 unitsMultiple dwelling (4 to 8 units)4,026 sq ft

Building options on a 33 × 122 ft lot

OptionStatusUnitsMax floor area
Multiple dwelling (4 to 8 units)Allowed6567 sq ft
Single detached house with secondary suiteAllowed22,503 sq ft
Single detached houseAllowed12,503 sq ft

Size limits for multiple dwelling on a 33 × 122 ft lot

Max floor area (FSR 0.50)567 sq ftFSD s.3.1.1.3
Max height37.7 ft, 3 storeysFSD s.3.1.2.1(b)
Site coverage35% of siteFSD s.3.1.2.5
Front setback27.9 ftFSD s.3.1.2.2
Side setback14.8 ftFSD s.3.1.2.3
Rear setback39.7 ftFSD s.3.1.2.4(b)
Rough building footprintup to 194 sq ftEstimate, not a design
Parking stalls requiredNoneParking By-law s.4.1.1, 4.1.3, 4.1.4

Source: Zoning and Development By-law No. 3575, First Shaughnessy District (FSD) District Schedule, June 2026 consolidation (rules approved 2026-10-14)

Your lot will differ.

Frontage, depth, lane access, corner lots and frequent-transit areas all change the answer. Search your address for a report on the real lot in Vancouver.

Check your address →orfind it on the map →

Common questions

How many units can I build in FSD zoning in Vancouver?

With a rear lane and outside a frequent-transit area, FSD allows up to 6 units on a 33 × 122 ft lot (multiple dwelling); up to 6 units on a 50 × 122 ft lot (multiple dwelling); up to 6 units on a 66 × 122 ft lot (multiple dwelling). Your own lot's frontage, depth and location change the result.

What is FSR?

Floor space ratio (FSR) is a building’s total floor area divided by the lot area. An FSR of 1.0 on a 4,026 sq ft lot allows about 4,026 sq ft of floor area across all storeys. Some bylaws, such as Burnaby’s R1, set no FSR at all; there BuildHere shows an effective FSR worked out from the height, setback and lot coverage limits.

Where do these FSD rules come from?

From Zoning and Development By-law No. 3575, First Shaughnessy District (FSD) District Schedule, June 2026 consolidation (rules approved 2026-10-14). Preliminary screening only. Verify with the City of Vancouver.

Other Vancouver zones

R1-1RM-2RM-3RM-3ARM-4RM-7RM-7ARM-8RM-8ARM-9ARM-10RM-11RM-12RT-2RT-3RT-5RT-7RT-8RT-10RT-11R3-1R3-2R3-3R5-1R5-2R5-3R5-4FM-1RA-1R4-1RM-1RM-5RM-5ARM-5BRM-5CRM-5DRM-6RM-9RM-9BRR-2ARR-2BRR-3ARR-3BRR-3CRT-1RT-4RT-4ART-9